Flow Measurement – Fluid Mechanics

Summary
In this experiment many different meters were used to measure fluid flow rate; the orifice plate, the venture meter, the rotameter and the weigh tank. Each meter works by its ability to alter a certain physical property of the flowing fluid and then allows this alteration to be measured. The measured alterations are linked directly to the flow rate and these measurements are subbed into adjusted equations to solve for it. The outcome of Each method is then analyzed, compared against each other.
1. Objectives

Save Time On Research and Writing
Hire a Pro to Write You a 100% Plagiarism-Free Paper.
Get My Paper

To introduce the student to three typical methods of measuring the flow rate of an incompressible fluid namely;

Venturi metre
Orifice plate
Rotor metre

To compare the accuracy of each device.
To give insight into appropriate industrial applications for each device.

2. Theory
Water enters and first flows through the Venturi meter, then through the Orifice plate, and then through the Rotor meter. On leaving the Rotor meter the water flows via a control valve to the weigh-tank of the hydraulic bench.
At the inlet and the outlet of each flow measuring device is a connection to the manometer board, this allows the head loss to be determined across each device. For an incompressible fluid flowing through a pipe the following equations apply:
Continuity, Q=V1A1=V2A2(1) Bernoulli’s P1ρ g+V122g+z1=P2ρ g+V222g+z2(2)
Venturi Rewriting Bernoulli’s equation for the experimental apparatus PAρ g+VA22g+zA=PBρ g+VB22g+zB
Since the apparatus is horizontal ZA=ZB therefore, PAρ g+VA22g=PBρ g+VB22g
Rearranging VB22g+VA22g=PAρ g+PBρ g
Since P/ρ g is the hydrostatic (pressure) head, h at any given point we can rewrite the above equation as,
VB22g+VA22g=hA-hB(3)
Where hA and hB are read directly from the apparatus. To solve for velocities, we rearrange equation (1),
VA=VBABAA Filling into equation (3),
VB22g+VBABAA22g=hA-hB(4)
Hence the only unknown as VB. Therefore, to find the flow rate, determine VB from equation (4) and then Q is given by. Q=VBAB (5)
Orifice Q is calculated using the same procedure as the Venturi meter using ports E and F as opposed to A and B.
However, because the orifice plate is less ideal, it causes turbulence in the flow it requires a correction factor known as the coefficient of discharge, K. For this apparatus K=0. 601 therefore, the calculated Q must be multiplied by K, Qactual=Qtheoretical × K
Rotor meter
The flow rate is read directly off the rotor meter calibration curve as seen in the graph h below.
3. Apparatus:
The bulk of the apparatus used in this experiment is as shown below on a labeled diagram.
The flow of water was manually varied by a screw-type tap. The weight balance is not shown but is acted on a counterbalancing weight system. In this experiment, a 4kg weight was dropped and the time was started. The length of time was determined by how long it would take for the water to raise the weight. This (with a 1:3 weight is to water ratio) allowed the mass flow rate to be calculated.
4. Orifice
Venturi Procedure: 1. Set flow rate to the maximum. 2. Record the monometer readings A, B, E, and F. 3. Measure the discharge using the weigh-tank. 4. Repeat steps 2 and 3 for 6 other flow rates. 5. Draw a graph of the volumetric flow rate measured by the weigh-tank versus volumetric flow rate measured by the other three devices (all on one graph). 6. Discuss the advantages and disadvantages of each device from an installation view.
5. Experimental Results:

Save Time On Research and Writing
Hire a Pro to Write You a 100% Plagiarism-Free Paper.
Get My Paper


Amm
Bmm
Emm
Fmm
Rota-meter
Flow rate (weigh – tank) @4kg (s)

1
378
131
349
86
21. 4
25

2
345
162
326
130
18. 4
31. 8

3
320
188
304
165
15. 2
37

4
298
202
288
191
12. 3
47. 5

5
282
222
274
211
9. 3
59. 4

6
266
236
262
232
5. 4
91. 5

 

Position
A
B
E
F

Diameter (m)
0. 026
0. 016
0. 051
0. 020

6. Sample Calculations
Venturi: As Q=VA, the volume (V) and the area (A) must be calculated first. Volume is found from the equation (4) as shown in theory being rearranged;
VB22g+VBABAA22g=hA-hB
VB2-VB2AB2AA2=hA-hB2g
VB21-AB2AA2=hA-hB2g
VB2=hA-hB2g1-AB2AA2
VB2=hA-hB2g1-AB2AA2
VB=hA-hB2g1-AB2AA2
From this equation, V can now be calculated using the results from the experiment. Calculation carried out for the first instance:
AA=5. 3093 × 10-4m2
AB=2. 0106 ×10-4m2
h = the height read from the manometer in the experiment.
VB=0. 378-0. 131(29. 8)1-(2. 0106 × 10-4)2(5. 3093 × 10-42)2
VB=4. 4120. 85659
VB=5. 6517
VB=2. 3773m/s
Now that the velocity at point B and the area of point B is calculated, Q can now be worked out;
QB=VBAB
QB=2. 3773 × (2. 0106 × 10-4)
Volumetric Flow Rate
B=4. 7799 × 10-4m3/s
To convert into kg/s;
QB=(4. 7799 × 10-4) / 1000
Mass Flow rate B=0. 4779kg/s
Orifice: To calculate the mass flow rate using the orifice method, calculations very similar to the venture method are used. The positions are now different so therefore the diameters are changed in finding Q. AA/VA and AB/VB are now obviously changed to AE/VE and AF/VF but otherwise the exact same method is used to find VF.
However, the overall mass flow rate has to be corrected by a factor of K=0. 0601 due to a less efficient apparatus being tested.
AE=2. 0428 × 10-3m2
AF=3. 1416 × 10-4m2
VF=hE-hF2g1-AF2AE2
VF=0. 349-0. 08629. 811-3. 1416 × 10-42. 0428 × 10-32
VF=5. 16. 97635
VF=5. 2851
VF=2. 298m3/s
Q=VFAF
Q=2. 2983. 1416 × 10-4
Q=7. 223 × 10-4
Now multiplied by correction factor and converted to kg/s; Q=7. 223 × 10-4)(0. 601)(1000) Q=0. 43406 kg/s
Rota-meter The mass flow of water is worked out in this method by feeding the results read from the rotor meter into the graph as shown below;
Weigh Tank
The ratio of the weight of the load to the weight of the water in this lab is 1:3. A weight was applied to the time the discharge was 4kg. Therefore the time taken for this discharge can allow us to calculate the mass flow rate as Mass flow Rate = KG/S.
So for the first test;
Q=4325
Q=0. 48kg/s
7. Calculated results


Venturi (kg/s)
Orifice (kg/s)
Rotameter(kg/s)
Weigh tank(kg/s)

1
0. 4779
0. 4341
0. 463
0. 48

2
0. 4116
0. 3747
0. 404
0. 3773

3
0. 3496
0. 3156
0. 341
0. 3243

4
0. 2981
0. 2636
0. 284
0. 2526

5
0. 2357
0. 2124
0. 224
0. 202

6
0. 1667
0. 1466
0. 152
0. 1312

8. Discussions
The measurement of fluid flow can prove very important in day to day applications. For example, the measurements of blood-flow rates in a human artery or the measurement of liquid oxygen in a rocket are hugely important in their field of work. Although the methods used in this lab may not all work in these cases, the selection of the proper instruments for a particular application is hugely important. Flow-rate-measurement devices frequently require accurate pressure and temperature measurements in order to calculate the output of the instrument so choosing the correct method of measurement is hugely important.
Each of the flow measurement devices used had its own advantages and disadvantages. Comparing the venturi meter the orifice plate there are some noticeable differences. Although both are suitable for clean or dirty fluids the orifice plate has a relatively low cost compared to the venturi meter. But on the other hand, the orifice plate does require a smaller diameter in comparison to the venturi meter. In day to day applications, these two factors could have a huge effect on the choice in the application. Cost is always a huge factor in any application decision and depending on the requirements for the application size could also play a vital role.
The weigh tank is a somewhat more basic approach to measuring the mass flow rate of a fluid. The human element of error in the timing of the displacement of the weight can be easily corrected by machinery and could prove very effective for applications measuring flow. The rotameter is also a simple but effective method of flow measurement. The simple effects of parallax are a disadvantage to this application but again in day to day modern applications, computerized sensory machines can correct this very easily.
9. Conclusion
Overall this lab was a success. The results are all within the range of having explainable errors such as;

The main error predicted is due to the ‘snowball effect’ in calculations, where a rounding off of results at the beginning of a number of equations has a greater effect on the end result. This rounding error can have greater effects than thought and can drastically vary the end result.
Parallax is another error caused across each application. The heights read across the manometers and the rotameter can be easily read wrong. Along with the meniscus of the fluid giving a false level and a wrong angle at the result reading can change the end result also.

Human error is always a small error to be taken into account, especially when using the stopwatch in the weight tank method of measuring the flow rate. The likelihood of reading the exact time needed is very small. This again can have a huge effect on the accuracy of the result achieved. By carrying out this laboratory students were able to become comfortable with calculations and equations that were run through in class. The ‘hands-on approach’ of this lab allows students to understand the theory better and this, in turn, results in easier revision when studying for exams.
Overall this laboratory and its results proved successful, with results accurate with an explainable percentage of error and with students having a greater understanding in this area.
10. Bibliography:

CIT laboratory manual: Fluid mechanics-B. S. Massey, Applied mechanics – J. D. Walker, Fluid mechanics – Irfan A. Khan, Mechanical Engineering Science- J. Hannah and M. J. Hiller.
Wikipedia – formulas / units confirmation
http://fetweb. ju. edu. jo – general information on each measuring meter used.

Place your order
(550 words)

Approximate price: $22

Calculate the price of your order

550 words
We'll send you the first draft for approval by September 11, 2018 at 10:52 AM
Total price:
$26
The price is based on these factors:
Academic level
Number of pages
Urgency
Basic features
  • Free title page and bibliography
  • Unlimited revisions
  • Plagiarism-free guarantee
  • Money-back guarantee
  • 24/7 support
On-demand options
  • Writer’s samples
  • Part-by-part delivery
  • Overnight delivery
  • Copies of used sources
  • Expert Proofreading
Paper format
  • 275 words per page
  • 12 pt Arial/Times New Roman
  • Double line spacing
  • Any citation style (APA, MLA, Chicago/Turabian, Harvard)

Our guarantees

Delivering a high-quality product at a reasonable price is not enough anymore.
That’s why we have developed 5 beneficial guarantees that will make your experience with our service enjoyable, easy, and safe.

Money-back guarantee

You have to be 100% sure of the quality of your product to give a money-back guarantee. This describes us perfectly. Make sure that this guarantee is totally transparent.

Read more

Zero-plagiarism guarantee

Each paper is composed from scratch, according to your instructions. It is then checked by our plagiarism-detection software. There is no gap where plagiarism could squeeze in.

Read more

Free-revision policy

Thanks to our free revisions, there is no way for you to be unsatisfied. We will work on your paper until you are completely happy with the result.

Read more

Privacy policy

Your email is safe, as we store it according to international data protection rules. Your bank details are secure, as we use only reliable payment systems.

Read more

Fair-cooperation guarantee

By sending us your money, you buy the service we provide. Check out our terms and conditions if you prefer business talks to be laid out in official language.

Read more
Live Chat+1 763 309 4299EmailWhatsApp

We Can Handle your Online Class from as low as$100 per week