Experimentally determine Young’s modulus, shear modulus and Poisson’s ratio of stainless steel rods using magnetostrictive resonance
Abstract
Young’s modulus (E) and the shear modulus (μ) of thin stainless steel rods, as well as Poisson’s ratio (σ), were experimentally found by determining the longitudinal and torsional resonant frequencies for different known lengths of rods using magnetostrictive resonance. Young’s modulus was found to be 140 GPa ±17 and shear modulus 59.2 GPa ±5.7. Poisson’s ratio was found for the rods of varying length and three of these were within right range at: 0.23±0.07 for the 0.417m rod, 0.13±0.04 for the 0.411m rod and 0.11±0.03 for the 0.251m rod.
This experiment aimed to determine Young’s modulus (E) and the shear modulus (μ) of thin stainless steel rods, as well as Poisson’s ratio (σ), by finding the longitudinal and torsional resonant frequencies for different known lengths of rods using magnetostrictive resonance. A drive coil connected to a power amplifier was used to vary the driving frequency and excite the steel rods. The vibrations of the steel rods due to the changing magnetic field were measured using a stereo cartridge connected to an oscilloscope.
, (1)
, (2)
where
, L is the length of the rod, and C are the wave velocities:
(3)
and
(4)
respectively, where E and μ are Young’s and shear moduli and ρ is density.
These equations are used to relate f to 1/L and thus find the elastic moduli.
Poisson’s ratio, σ, is the ratio of change in dimensions laterally and longitudinally of a material “placed under a uniform longitudinal tensile (compressive) load” and is normally around 0.3 [3, p. 4]. Davis and Opat give this as
, (5)
where γ is given by
[2] . (6)

The method was adapted from that used by Davis and Opat in “Elastic vibrations of rods and Poisson’s ratio” [2]. Six stainless steel rods of varying lengths between 0.102 and 0.417 m were individually clamped at their centres by three pointed screws to reduce contact and thus damping. The rods were then positioned to pass through a drive coil, also close to their centre, and finally the stereo cartridge stylus was positioned at the top of the rod, off centre on the flat end, as shown in Figure 1.Figure 1: Clamp stand with rod clamped in the centre, coil clamped slightly above, and the stereo cartridge positioned above the rod to pick up vibrations. Foam used under clamp stand to attempt to reduce back ground vibrations.
This positioning allowed for the detection of and distinction between longitudinal and torsional resonances. The two outputs of the stereo cartridge each respond to different component of motion of the stylus at 45Ëš to the horizontal. Figure 2 is a diagram of the stereo cartridge stylus and placement on the end of the rod from Davis and Opat [2] which shows how it was possible to differentiate between longitudinal and torsional modes. Whenever resonance occurred and the two channels were in phase it was longitudinal as both directions of motion moved up and down at the same time. When resonance occurred out of phase it was torsional as the rotation meant the two directions of motion were outputting opposite signals.

Figure 2: From Davis and Opat’s “Elastic vibrations of rods and Poisson’s ratio” [2]. Stereo stylus design (a) and placement on the rod (b)
The drive coil was connected to a power amplifier and the output frequency was varied. The two outputs of the stereo cartridge were connected to the two channels of an oscilloscope. In this way, it was possible to vary the frequency until the amplitude shown on the oscilloscope was a maximum and record the frequency. This was repeated for rods of different length. Also recorded were the mass and diameter of each rod analysed in order to find the density since each steel rod had slightly different composition.

Figure 3: Resonant frequencies (kHz) of longitudinal vibrations for n=1 (fundamental) plotted against the reciprocals of the lengths of the rods (m-1).
The gradient of the fitted line in Figure 3 is 2.095 kHz ±0.129. Using equations (1) and (3) with n=1, this gives E=140 GPa ±17 using ρsteel =7970 kg m-3 [3, p. 435], or using the average of the densities of steel recorded (ρ =8020 kg m-3 ±700) E=141 GPa ±20.

Figure 4: Resonant frequencies (kHz) of torsional vibrations for n=1 (fundamental) plotted against the reciprocals of the lengths of the rods (m-1).
The gradient of the fitted line in Figure 3 is 1.363 kHz ±0.066. Using equations (2) and (4) with n=1, this gives μ= 59.2 GPa ±5.7 using ρsteel =7970 kg m-3 [3, p. 435], or using the average of the densities of steel recorded (ρ =8020 kg m-3 ±701) μ=59.6 GPa ±7.8.
Poisson’s Ratio (σ) is found from the longitudinal and torsional resonant frequencies of the same rod and the same mode (n=1) using equations (5) and (6). This quantity varies for each rod, again evidence of a large random error in the resonant frequencies. Table 1 shows the different values of σ. The errors for Poisson’s ratio are calculated based on the random error in each of the resonant frequencies.
|
Length /m±3×10-3 |
Poisson’s Ratio |
|
0.417 |
0.23±0.07 |
|
0.411 |
0.13±0.04 |
|
0.367 |
0.7±0.2 |
|
0.262 |
0.04±0.01 |
|
0.251 |
0.11±0.03 |
Table 1: Poisson’s Ratio for different lengths of rods for mode n=1 from equations (5) and (6)
Young’s modulus and shear modulus are in the same order of magnitude as literature values, with experimentally determined E=140GPa compared to a literature value of around 180 GPa for stainless steel [4] or 194 according to Blevins [3]. Experimentally determined shear modulus was found to be μ=59.2GPa compared to 77.2Gpa [5]. The result for the shear modulus is more accurate, and this is confirmed by the smaller random error. The errors due to the equipment for these measurements are very small, since the frequency could be varied to within 0.1 Hz and differences in amplitudes on the oscilloscope could be observed within 2Hz. However, with only 5 points, and no modes higher than n=1 to confirm the resonant frequencies, as well as a limited few lengths, there are not enough points of data to obtain a truly accurate result.
For Poisson’s Ratio, there is a large variation between the values for each rod, which is in part linked to the large random error in the frequency values themselves, but which may also be due in part to the differences in the type of steel used in each rod. They are almost all of the right order of magnitude, and some are very close to the literature value of 0.265 [3, p. 435].
One major problem encountered was the fact that no resonant frequencies above 15kHz were observed. Whether this is a limitation of the stereo cartridge or due to the extremely small width of the resonances at these high frequencies, or a combination of both, is unclear. However, it may be possible to detect resonances at higher frequencies with a more sensitive stereo cartridge or a more accurate power amplifier. While the power amplifier used was adjustable to 0.1Hz at low frequencies, above 10kHz this was reduced to 1Hz.
Another improvement to the method is to use more and longer rods. This is similar to the problem addressed above of high frequency resonances being difficult to detect. No resonances were found for the shortest rod available because all, including the n=1 mode, were too high. With longer rods, and more data points, a more accurate result could be
In some cases, it was difficult to record data accurately or to detect resonances due to background vibrations. For example, the movement of a chair 5m away was enough to create a very unstable oscilloscope trace due to the sensitivity of the stereo cartridge to low frequencies. This was the case despite efforts to reduce the background vibrations by placing the clamp stand set up on foam.
An extension to non-ferrous materials was attempted by using a small piece of steel with two longer pieces of aluminium attached with screws on either side. However, only one strong resonance was detected, which was not close to the predicted resonance of aluminium, and since the issues mentioned above meant that it was difficult to obtain enough data even for steel rods it was decided not to pursue this. As Davis and Opat put it, “Inhomogeneities in the structure of the rod can lead to coupling of the different vibrational modes and the description of the oscillating rod rapidly becomes more complex.” [2]. A more appropriate method for generating vibrations in rods of non-ferrous materials is outlined by Meiners and may be found in “Physics Demonstration Experiments” on page 439 [6].
The longitudinal and torsional resonance frequencies for stainless steel rods of varying known length were measured and used to determine Young’s modulus of 140 GPa ±17 and shear modulus of 59.2 GPa ±5.7 using literature values for density of steel. Poisson’s ratio was found for the rods of varying length and three of these were within right range at: 0.23±0.07 for the 0.417m rod, 0.13±0.04 for the 0.411m rod and 0.11±0.03 for the 0.251m rod. The random error in the resonance frequencies was large, which meant that none of the results are very accurate. The accuracy could be improved with more data form more rods.
References
|
[1] |
J. P. Joule, “Mr. J. P. Joule on the Effects of Magnetism upon the Dimensions of Iron and Steel Bars,” The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science, vol. XXX (30) Third Series, no. 199, pp. 76-86, February 1847. |
|
[2] |
T. J. Davis and G. I. Opat, “Elastic vibrations of rods and Poisson’s ratio,” American Journal of Physics, vol. 51, no. 2, 1983. |
|
[3] |
R. D. Blevins, Formulas for natural frequency and mode shape, New York: Van Nostrand Reinhold Company, 1979. |
|
[4] |
“The Engineering ToolBox-Young’s Modulus,” [Online]. Available: http://www.engineeringtoolbox.com/young-modulus-d_417.html. [Accessed 30 March 2014]. |
|
[5] |
“The Engineering ToolBox- Modulus of Rigidity,” [Online]. Available: http://www.engineeringtoolbox.com/modulus-rigidity-d_946.html. [Accessed 30 March 2014]. |
|
[6] |
H. F. Meiners, Physics Demonstration Experiments, vol. 1, New York: The Ronald Press Company, 1970. |
Acknowledgements
Thanks to collaborator in Data Collection: Bivu Nepaune
1
Why Work with Us
Top Quality and Well-Researched Papers
We always make sure that writers follow all your instructions precisely. You can choose your academic level: high school, college/university or professional, and we will assign a writer who has a respective degree.
Professional and Experienced Academic Writers
We have a team of professional writers with experience in academic and business writing. Many are native speakers and able to perform any task for which you need help.
Free Unlimited Revisions
If you think we missed something, send your order for a free revision. You have 10 days to submit the order for review after you have received the final document. You can do this yourself after logging into your personal account or by contacting our support.
Prompt Delivery and 100% Money-Back-Guarantee
All papers are always delivered on time. In case we need more time to master your paper, we may contact you regarding the deadline extension. In case you cannot provide us with more time, a 100% refund is guaranteed.
Original & Confidential
We use several writing tools checks to ensure that all documents you receive are free from plagiarism. Our editors carefully review all quotations in the text. We also promise maximum confidentiality in all of our services.
24/7 Customer Support
Our support agents are available 24 hours a day 7 days a week and committed to providing you with the best customer experience. Get in touch whenever you need any assistance.
Try it now!
How it works?
Follow these simple steps to get your paper done
Place your order
Fill in the order form and provide all details of your assignment.
Proceed with the payment
Choose the payment system that suits you most.
Receive the final file
Once your paper is ready, we will email it to you.
Our Services
No need to work on your paper at night. Sleep tight, we will cover your back. We offer all kinds of writing services.
Essays
No matter what kind of academic paper you need and how urgent you need it, you are welcome to choose your academic level and the type of your paper at an affordable price. We take care of all your paper needs and give a 24/7 customer care support system.
Admissions
Admission Essays & Business Writing Help
An admission essay is an essay or other written statement by a candidate, often a potential student enrolling in a college, university, or graduate school. You can be rest assurred that through our service we will write the best admission essay for you.
Reviews
Editing Support
Our academic writers and editors make the necessary changes to your paper so that it is polished. We also format your document by correctly quoting the sources and creating reference lists in the formats APA, Harvard, MLA, Chicago / Turabian.
Reviews
Revision Support
If you think your paper could be improved, you can request a review. In this case, your paper will be checked by the writer or assigned to an editor. You can use this option as many times as you see fit. This is free because we want you to be completely satisfied with the service offered.